MSDS
2712803
|
MATERIAL SAFETY DATA SHEET
|
Photovolt Instruments
Inc. Phone: 952-848-2000 |
EMERGENCY & MSDS CONTACT 3E Company |
|
PHOTOVOLT Water Standard 2%
CHEMICAL NAME & SYNONYMS DOT CLASS SARA
TITLE 313
KF Water Standard, 2.0%; 3/II Yes Methyl Alcohol; Methanol; Wood Alcohol TSCA listed - Yes FORMALA REPORTABLE QUANTITY F.W. CAS# CH3OH 98% 2270 kg 32.04 67-56-1 H2O 2% N/A 18.02 7732-18-5 PHYSICAL DATA Density 0.79; Melting point -97.8C; Boiling point 64.8C; Vapor pressure 100 mm at 21C. Vapor density 1.11; 100% volatile. Miscible with water, ethanol or ether. APPEARANCE & ODOR Clear colorless liquid. Slight odor of alcohol. REACTIVITY & CONDITIONS TO AVOID Stable. No spontaneous self-reactions. Incompatible with oxidants. FIRE HAZARDS
Flammable with heat spark or flame. Flame is nearly
EXTINGUISHER
FLASHPOINT LEL
UEL
Dry chemical, foam, C02. 12C 6.0% 36.5% HEALTH HAZARDS Irritating to skin, eyes and on inhalation. Toxic effects on CNS, narcotic properties. Toxic internally LD50 (oral-rat) 5628 mg/kg. 50-250ml is fatal dose to humans. Smaller doses may cause blindness. Other symptoms include dizziness, blurring of vision, headaches, nausea, unconsciousness and intoxication. OSHA PEL/ACGIH TLV: TWA: 200 ppm. DTLVS. ACGIH STEL 250 ppm. No evidence of carcinogenicity. SPECIAL PRECAUTIONS
Wear goggles and rubber gloves while handling. Keep
FIRST AID
Wash skin and eyes thoroughly with water. Get
SPILLS & LEAKS
Take up spill in absorbent and incinerate. Wash up DATE: PREPARED BY: 1/28/08 JHN |
| Photovolt
Instruments Inc. email:
sales@photovolt.com PHONE: 1-952-848-2000 FAX 1-952-926-5498 |