MSDS 2712804

MATERIAL SAFETY DATA SHEET

Photovolt Instruments Inc.

6323 Cambridge St.

Minneapolis, MN 55416

Phone: (800) 222-5711

EMERGENCY & MSDS CONTACT

3E Company

(800) 451-8346

(619) 677-0150

SECTION 1 - IDENTIFICATION

Product Name: Methyl Alcohol 1/2 Gallon

Product Number: 27-128-04 Volume: 1875mL

Chemical Family: Solvent Synonyms: Aquatest Reagent

Molecular Formula: Mixture CAS#: Mixture

SECTION 2 - INGREDIENTS

Ingredient

CAS#

%

Formula

PEL,ppm

TLV,ppm

SARA Title III

Methanol

67-56-1

98v/v

CH3OH

200

200

Yes

SECTION 3 - PHYSICAL DATA

 

 

Ingredient

Boiling Point ° F(° C)

Solubility Specification

H2O

 

Gravity

Melt Point ° C

Vapor Density

Air=1

Vapor Pressure mm Hg/° C

Appearance / Odor

Methanol

147(84)

Soluble

0.8

-97.8

1.11

100/21.2

Clear/Mild

SECTION 4 - FIRE AND EXPLOSION HAZARD DATA

Flash Point: 53° F (12° C) closed cup; Product is very flammable.

Extinguisher Media: Carbon dioxide, dry chemical, alcohol foam, water.

Special Fire Fighting Procedures: Wear NIOSH/MSHA approved self-contained breathing apparatus, flame and chemical resistant clothing, hats, boots and gloves.

SECTION 5 - HEALTH DATA

A. Animal Toxicity: LD50: Oral Rat 5,628 mg/Kg

LC50: No Data

B. Effects of Exposure:

1. Acute Effects

a. Ingestion: Large quantities may cause GI disturbance, CNS depression, dizziness, unconsciousness, blindness, and death.

b. Skin Contact: Causes skin irritation.

c. Eye Contact: Causes eye irritation, possible blindness.

d. Inhalation: Irritating to mucous membranes and upper respiratory tract.

e. Medical conditions, if any, aggravated: Diseases of the eyes, liver, kidneys, or skin.

f. Most likely route of entry: skin, inhalation

2. Chronic Effects

Product contains Methanol. This substance is known to produce adverse reproductive effects in laboratory animals.

a. Skin Contact: Dry and cracked skin.

b. Inhalation: CNS depression, kidney and liver damage.

C. Emergency and First Aid Procedures

Ingestion: Call Poison Control Center for assistance.

Eye and Skin Contact: Immediately and continuously flush with flowing water. For exposure involving a significant quantity of material, contact a physician as soon as possible.

SECTION 6 - REACTIVITY

Incompatibility: Oxidizing agents, perchlorate acid, sodium hydroxide

Hazardous Decomposition Products: Carbon Monoxide

Conditions to Avoid: Incompatibles

Stability: Stable

Hazardous Polymerization: Will not occur

Other: No additional data

SECTION 7 – ENVIRONMENTAL INFORMATION

RCRA Code: D001

TSCA Registered: Yes

Spill and Leak Procedures: Wearing full protective equipment, cover spill with dry sand or vermiculite. Mix well and carefully transfer to a container.

Waste Disposal: Consult state, local, or federal EPA regulations for proper disposal.

SECTION 8 – PROTECTION INFORMATION

Ventilation Requirements: Laboratory fume hood

Respiratory Protection: High efficiency organic vapor respirator

Skin Protection: Wear impervious protective clothing including boots, gloves, lab coat, apron, or coveralls to prevent skin contact.

Eye/Face Protection: ANSI approved safety goggles

SECTION 9 – SPECIAL PRECAUTIONS

Handling and Storage: Keep containers tightly closed. Store in a standard flammable liquid storage cabinet. Wash thoroughly after use.

Other Precautions: Lab coat and apron, flame and chemical resistant coveralls, eyewash capable of sustained flushing, safety drench shower and hygienic facilities for washing.

SECTION 10 – TRANSPORTATION INFORMATION U.S. D.O.T.

Per 49 CFR 172

Shipping Description: Methanol Solution

Flammable Liquid, UN1993, PG II

SECTION 11 – COMMENTS

Danger: Flammable, irritates skin and eyes

Employers should use this information only as a supplement to other information gathered by them, and should make independent judgement of suitability of this information to ensure proper use and protect the health and safety of employees. This information is furnished without warranty, and any use of this product not in conformance with this Material Safety Data Sheet, or in combination with any other product or process, is the responsibility of the user.


DATE: 1/28/08
PREPARED BY: JHN
        

 


BACK TO MAIN INDEX

   Photovolt Instruments Inc.                            email: sales@photovolt.com
   PHONE: 1-952-848-2000                                                FAX 1-952-926-5498